KP-8850 Electrosurgical Unit Analyzer
Discover the KP-8850 Electrosurgical Unit Analyzer from Kingpo
Technology Development Limited, a cutting-edge device designed for
precise testing and analysis of high-frequency electrosurgical
units (ESUs). Ideal for medical device manufacturers, quality
control labs, and biomedical engineers, this analyzer ensures
compliance with safety standards like IEC 60601-2-2. Whether you're
searching for "electrosurgical unit analyzer," "high-frequency ESU
tester," or "ESU power analyzer," the KP-8850 delivers accurate
measurements for power, leakage current, and more.
Overview of the KP-8850 Electrosurgical Unit Analyzer
The KP-8850 is a versatile high-frequency electrosurgical analyzer
engineered to evaluate the performance and safety of
electrosurgical units. It supports monopolar and bipolar modes,
offering comprehensive testing capabilities including power output,
load power curves, high-frequency leakage current, and REM/CMQ
(Return Electrode Monitoring/Contact Quality Monitoring) functions.
Key highlights:
- High Precision Measurements: Accurate readings for power (0-500W), voltage (0-5kV peak), and
current (2mA-2000mA RMS).
- User-Friendly Interface: 10-inch full-color LCD touchscreen with waveform display, zoom
functionality, and intuitive controls.
- Versatile Connectivity: USB, HDMI, LAN ports for data export, external display, and
network integration.
- Safety-Focused Design: Built-in grounding, high-voltage warnings, and compliance with
international safety standards.
This analyzer is essential for ensuring ESUs operate safely and
effectively in surgical environments, minimizing risks like burns
or electrical shocks.
Key Features of the KP-8850 ESU Analyzer
Advanced Testing Modes
- Continuous Mode: For cutting modes with sustained high-frequency output.
- Pulse Mode: Supports three pulse variations for coagulation or blended modes,
with pulse durations from 0-500ms.
- Delay Mode: Measures delayed signal outputs.
Load Impedance Simulation
- Range: 0-6400Ω with 1Ω steps.
- Accuracy: ±1% (≥50Ω), ±3% (≥10Ω & <50Ω).
- Rated Power: Up to 500W for higher loads, supporting external loads
for extended testing.
High-Frequency Leakage Current Testing
- Range: 2mA-500mA.
- Supports multiple network configurations (Leakage Test 1a, 1b, 2,
3a, 3b) for thorough safety assessments.
- Bandwidth: 10kHz-250MHz.
REM/CMQ Testing
- Simulates return electrode contact with 0-6400Ω range.
- Quick short-circuit (0Ω) or open-circuit (+∞Ω) selections for rapid
verification.
Data Management and Display
- 500GB internal storage for saving test results, waveforms, and
Excel exports.
- Oscilloscope output (1V/A) for external monitoring.
- HDMI extension for large-screen viewing of power distribution
curves.
Physical and Communication Specs
- Dimensions: 500x450x220mm; Weight: 23kg.
- Interfaces: USB x2, Ethernet, HDMI.
- Power Supply: 220VAC, 50/60Hz.
Technical Specifications
| Parameter | Specification |
|---|
| Power | Range: 0-500W; Resolution: 0.1W; Accuracy: ±2.5% or ±1W |
| Voltage | Range: 0-5kV (peak); Accuracy: ±2% |
| Current | Range: 2mA-2000mA RMS; Resolution: 0.1mA; Accuracy: ±1.5% |
| HF Leakage Current | Range: 2mA-500mA; Resolution: 0.1mA; Accuracy: ±2.5% |
| Bandwidth | 10kHz-250MHz |
| Load Impedance | 0-6400 Ω (1 Ω step); Accuracy: ±1% (≥50Ω), ±3% (10-50Ω) |
| Internal Load Power Rating | 10-101 Ω: 100W; 101-201 Ω: 200W; 201-501 Ω: 300W; 501-6400 Ω: 500W |
| Crest Factor | 1.4-20 |
| REM/CMQ | 0-6400 Ω (1 Ω step); Accuracy as above |
| Display | 10-inch full-color LCD touchscreen; Supports graphs and curves |
| Storage | 500GB |
| Interfaces | USB, Ethernet, HDMI |
| Pulse Modes | Supports external/internal triggering; High/Low thresholds (mA) |
| Automatic Testing | Yes |
How to Use the KP-8850 Electrosurgical Unit Analyzer
Front Panel Overview
- Power Button: Starts the device.
- USB Ports: For external keyboard/mouse or data transfer.
- Touchscreen: Main interface for operations.
- Ports: Active (surgical electrode), Dispersive 1/2 (neutral electrode),
Earth (ground), CMQ 1/2.
Rear Panel Overview
- HDMI: External display.
- LAN: Network connection.
- Power Input: 220VAC, 50/60Hz.
- BNC Output: For oscilloscope calibration.
- Foot Switch: Optional trigger.
Setup and Connection
- Power On: Connect to grounded outlet, press Power button.
- Connect EUT (Electrosurgical Unit):
- Monopolar: Active to surgical electrode; Dispersive 1/2 to neutral
electrode.
- Bipolar: Active to one electrode; Dispersive 1 to the other.
- Ensure grounding to prevent shocks—high voltages up to 1kV+.
- Select Mode: Choose Continuous, Pulse, or Delay via touchscreen.
- Set Parameters: Load impedance, polarity (monopolar/bipolar),
thresholds.
- Start Test: Press "Start" for real-time data and waveforms.
- Pause/Stop: Analyze waveforms; save results as Excel or images.
- For leakage current tests, follow specific network diagrams (e.g.,
Leakage Test 1a: Active to surgical electrode, Earth grounded).
Safety Precautions
- Always ground the device and EUT.
- Avoid contact with high-voltage parts—use provided silicone
high-voltage cables (rated 2kV+).
- Do not operate in wet environments.
- Follow warnings: High voltage (>1000V) can cause injury or
death.
Why Choose the KP-8850 for ESU Testing?
The KP-8850 stands out in the market for its accuracy, ease of use,
and comprehensive features. It's perfect for R&D, production
testing, and maintenance of electrosurgical devices. With support
for pulse modes and external loads, it handles complex scenarios
like coagulation testing. Backed by Kingpo's warranty: 1-year free
repair (excluding consumables).
Contact us at www.kingpo.hk for pricing, demos, or custom inquiries.
FAQ: Common Questions About the KP-8850 Electrosurgical Unit
Analyzer
What is an Electrosurgical Unit Analyzer?
An electrosurgical unit analyzer, like the KP-8850, is a
specialized test instrument used to measure the output power,
voltage, current, and leakage of high-frequency ESUs. It ensures
devices meet safety standards and perform reliably in surgery.
How accurate is the KP-8850?
It offers high accuracy: ±2.5% for power and leakage current, ±2%
for voltage, and ±1.5% for current. Load impedance is precise to
±1% for most ranges.
Does the KP-8850 support bipolar and monopolar testing?
Yes, it supports both. Select polarity in the parameters menu for
seamless switching.
Can I export test data from the KP-8850?
Absolutely. Save to 500GB internal storage as Excel files or
graphs. USB and Ethernet allow easy transfer to PCs.
What safety features does the KP-8850 have?
It includes grounding terminals, high-voltage warnings, and
prohibited action icons. Always use grounded outlets and avoid
direct contact with live parts.
Is the KP-8850 compatible with external displays?
Yes, via HDMI for extended viewing of waveforms and curves.
How do I perform REM/CMQ tests on the KP-8850?
Connect electrodes to CMQ ports, set load (0-6400Ω), and test for
short/open circuits. Results display contact quality instantly.
What is the warranty for the KP-8850?
One-year free warranty from purchase date (invoice-based). Contact
Kingpo for repairs or replacements.
For more details on "electrosurgical analyzer setup" or "ESU
leakage testing," explore our resources or reach out!