    IEC 60335-2-40 Annex NN Flame Arrest Enclosure Verification Test For A2L Refrigerants

    Ask Lasest Price
    Brand Name : kingpo
    Model Number : KP-FT3541
    Certification : ISO 17025
    • Product Details
    • Company Profile

    IEC 60335-2-40 Annex NN Flame Arrest Enclosure Verification Test For A2L Refrigerants

    IEC 60335-2-40 Annex NN Flame Arrest Enclosure Verification Test for A2L Refrigerants

    Product Introduction

    The KP-FT3541 Dielectric Strength Apparatus is specifically designed to meet the requirements of IEC 60335-2-40 Annex NN for verifying the flame arrest enclosure of A2L refrigerants. This apparatus is crucial for ensuring the safety and reliability of refrigeration systems by conducting rigorous ignition tests on refrigerants.
    The KP-FT3541 is equipped with a high-precision 15 kV source capable of producing a 30 mA spark across a 6.4 mm gap for 0.3 s ± 0.05 s. This setup is designed to simulate real-world ignition conditions, providing accurate and reliable test results. The apparatus is built to stringent standards, ensuring that it meets the specific requirements for testing A2L refrigerants as outlined in IEC 60335-2-40 Annex NN.

    Core Parameters

    Parameter

    Specification

    Model

    KP-FT3541

    Dielectric Strength

    15 kV source

    Spark Current

    30 mA

    Spark Gap

    6.4 mm

    Spark Duration

    0.3 s ± 0.05 s

    Test Purpose

    Verification of flame arrest enclosure for A2L refrigerants

    dry-bulb temperature32 °C
    dew point temperature27 °C

    Standard Compliance

    IEC 60335-2-40 Annex NN

    Features

    • High Precision: The KP-FT3541 features a high-precision 15 kV source, ensuring accurate and consistent test results.
    • Safety: Designed to meet the safety standards for testing A2L refrigerants, the KP-FT3541 provides a reliable and safe testing environment.
    • Ease of Use: The apparatus is user-friendly, with clear instructions and a straightforward setup process.
    • Compliance: Fully compliant with IEC 60335-2-40 Annex NN, ensuring that your refrigeration systems meet the required safety standards.

    Application

    The KP-FT3541 Dielectric Strength Apparatus is ideal for laboratories and testing facilities that require precise and reliable testing of A2L refrigerants. It is particularly useful for verifying the flame arrest enclosure in refrigeration systems, ensuring that they are safe for use in various applications.

    Conclusion

    The KP-FT3541 Dielectric Strength Apparatus is a vital tool for conducting flame arrest enclosure verification tests on A2L refrigerants. Its high-precision design and compliance with IEC 60335-2-40 Annex NN make it a reliable choice for ensuring the safety and reliability of refrigeration systems. Whether you are a manufacturer, a testing facility, or a research institution, the KP-FT3541 provides the accuracy and safety you need for your refrigerant testing needs.
    Flame arrest enclosure verification test for A2L refrigerants
    Flame arrest enclosure verification test for A2L refrigerants
    Quality IEC 60335-2-40 Annex NN Flame Arrest Enclosure Verification Test For A2L Refrigerants for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: KingPo Technology Development Limited
    *Subject:
    *Message:
    Characters Remaining: (0/3000)